Communication Protocol : UART
Product Type£ºEN06 Display
Product Voltage£º24V/36V/48V
Product Plug£º5Pin+ 2Pin
Cable Length£º1650mm/65in
Holder Diameter£º¥õ22.2mm/0.87in
Characteristic£ºUSB interface
Setting for LCD EN06
1.P01: Backlight Brightness (1: darkest; 3: brightest)
2.P02: Mileage Unit (0: KM; 1: MILE)
3.P03: Voltage Class 24V/36V / 48V
4.P04: Auto-Sleep Time
(0: never, other valuemeansdisplaysleep interval) Unit: minute
5.P05: Power Assist Gear
0/3 Gear Mode: Gear 1: 2V Gear 2: 3V Gear 3: 4V
1/5 Gear Mode: Gear 1: 2V Gear 2: 2.5V Gear 3: 4VGear 4: 3.5V Gear 5: 4V
6.P06: Wheel Diameter Unit: inch Precision: 0.1
7.P07: Magnet Steel Number (for Speed Test) Range: 1-100
8.P08: Speed Limit
Range: 0-50km/h, parameter 50 indicates no speed limit.
1. Non-communications status (panel-controlled)
Setting for LCD EN06
P01: Backlight Brightness (1: darkest; 3: brightest)
P02: Mileage Unit (0: KM; 1: MILE)
P03: Voltage Class 24V/36V / 48V
P04: Auto-Sleep Time
(0: never, other valuemeansdisplaysleep interval) Unit: minute
P05: Power Assist Gear
0/3 Gear Mode: Gear 1: 2V Gear 2: 3V Gear 3: 4V
1/5 Gear Mode: Gear 1: 2V Gear 2: 2.5V Gear 3: 4VGear 4: 3.5V Gear 5: 4V
P06: Wheel Diameter Unit: inch Precision: 0.1
P07: Magnet Steel Number (for Speed Test) Range: 1-100
P08: Speed Limit
Range: 0-50km/h, parameter 50 indicates no speed limit.
1. Non-communications status (panel-controlled)
When the current speed exceeds the speed limit, the PWM output will be shut down; when the current speed falls to lower than the speed limit, the PWM output will be activated and the driving speed will be set as the current speed ±1km/h (only applies to assist power speed, not applicable to the handlebar speed).
2. Communications status (controller-controlled)
The driving speed will be kept constant as the limited value.
Error Value: ±1km/h (applicable to both the assist power/handlebar speed)
Note: The above-mentioned values are measured by metric unit (kilometers). When the measuring unit is switched to imperial unit (mile), the speed value displayed on the panel will be automatically switched to corresponding imperial unit, however the speed limit value in the imperial unit interface won¡¯t change accordingly.
P09: Direct Start / Kick-to-Start Setting
0: Direct Start
1: Kick-to-Start
P10: Drive Mode Setting
0: Power Assist ? The specific gear of the assist drive decides the assist power value. In this status the handlebar does not work.
1: Throttle Mode ? The vehicle is driven by the handlebar. In this status the power gear does not work.
2: Power Assist + Throttle ? Electric drive does not work in zero-start status.
P12: Power Assist Intensity Range: 0-5
P13: Power Magnet Steel Number 5 / 8 / 12pcs
P14: Current Limit Value: 12A by default; Range: 1-20A
P15:Under-voltage:Choose according to your set
P16: ODO Zero-OutSetting for LCD EN06
P01: Backlight Brightness (1: darkest; 3: brightest)
P02: Mileage Unit (0: KM; 1: MILE)
P03: Voltage Class 24V/36V / 48V
P04: Auto-Sleep Time
(0: never, other valuemeansdisplaysleep interval) Unit: minute
P05: Power Assist Gear
0/3 Gear Mode: Gear 1: 2V Gear 2: 3V Gear 3: 4V
1/5 Gear Mode: Gear 1: 2V Gear 2: 2.5V Gear 3: 4VGear 4: 3.5V Gear 5: 4V
P06: Wheel Diameter Unit: inch Precision: 0.1
P07: Magnet Steel Number (for Speed Test) Range: 1-100
P08: Speed Limit
Range: 0-50km/h, parameter 50 indicates no speed limit.
1. Non-communications status (panel-controlled)
When the current speed exceeds the speed limit, the PWM output will be shut down; when the current speed falls to lower than the speed limit, the PWM output will be activated and the driving speed will be set as the current speed ±1km/h (only applies to assist power speed, not applicable to the handlebar speed).
2. Communications status (controller-controlled)
The driving speed will be kept constant as the limited value.
Error Value: ±1km/h (applicable to both the assist power/handlebar speed)
Note: The above-mentioned values are measured by metric unit (kilometers). When the measuring unit is switched to imperial unit (mile), the speed value displayed on the panel will be automatically switched to corresponding imperial unit, however the speed limit value in the imperial unit interface won¡¯t change accordingly.
P09: Direct Start / Kick-to-Start Setting
0: Direct Start
1: Kick-to-Start
P10: Drive Mode Setting
0: Power Assist ? The specific gear of the assist drive decides the assist power value. In this status the handlebar does not work.
1: Throttle Mode ? The vehicle is driven by the handlebar. In this status the power gear does not work.
2: Power Assist + Throttle ? Electric drive does not work in zero-start status.
P12: Power Assist Intensity Range: 0-5
P13: Power Magnet Steel Number 5 / 8 / 12pcs
P14: Current Limit Value: 12A by default; Range: 1-20A
P15:Under-voltage:Choose according to your set
P16: ODO Zero-Out